1The units (6.1)
| Unit | Symbol | Quantity | Used in this topic for |
|---|---|---|---|
| ampere | A | current | current in a wire, coil, electromagnet or motor; primary and secondary currents Ip, Is |
| volt | V | voltage | induced voltage; primary and secondary voltages Vp, Vs |
| watt | W | power | power into and out of a transformer, V × I |
1 W = 1 V × 1 A, because power = current × voltage (→ 2.4).
Transformer questions often use prefixes:
1 kV = 1000 V 1 kW = 1000 W 1 MW = 1 000 000 W 1 mA = 0.001 A
Convert to V, A and W before using power = voltage × current. In the turns-ratio equation (→ 6.19) the two voltages only need the same unit — both in kV is fine.
Example: 2 MW is sent along a cable at 400 kV. I = P ÷ V = 2 000 000 W ÷ 400 000 V = 5 A.
A turns ratio (Np : Ns) is a pure number — it has no unit.