EEasy IGCSELabTracker

On a phone the notes, quizzes and tracker work fine. The 3D models and the practice lab are made for a laptop.

Specification points 6.15–6.20 ·

inducing a voltage and the factors that affect its size, generators, the structure and action of a transformer, step-up and step-down transformers in transmission, the turns-ratio equation and input power = output power.

1Inducing a voltage (6.15)

Definition

Electromagnetic induction — a voltage is induced across a conductor when it moves through a magnetic field (cutting field lines) or when the magnetic field through a coil changes. If the conductor is part of a complete circuit, the induced voltage drives a current.

A voltage is induced only while field lines are being cut or the field is changing. Reversing the motion or the field reverses the voltage.

Size of the induced voltage — increase it by
  • moving the conductor or magnet faster, so field lines are cut or the field changes more quickly;
  • a stronger magnet (stronger magnetic field);
  • more turns on the coil.
Inducing a voltage: a wire moved through a magnetic field, and a magnet moved into a coil (a) wire between magnetic poles N S wire moved up or down: cuts field lines → voltage wire moved along the lines, or held still: no voltage (b) magnet and coil S N push in 0 centre-zero meter coil
Figure 1. Two ways to induce a voltage.

Move the magnet into the coil

Loading the interactive…

What you do (Figure 1b) Meter
push the N pole into the coil deflects one way
hold the magnet still inside the coil zero — nothing is changing
pull the N pole out deflects the other way
push the S pole in deflects the other way
push the N pole in faster larger deflection

2Generators (6.16)

  • Coil turned in a magnetic field (a): the sides of the coil cut the field lines, inducing a voltage. Every half turn each side moves the opposite way through the field, so the voltage reverses — the output is alternating (a.c.). Slip rings and brushes connect the turning coil to the circuit without twisting the wires.
  • Magnet turned inside a coil (b): the field through the fixed coil keeps changing and reverses every half turn, so an alternating voltage is induced in the coil.
Two generators: a coil turned in a magnetic field, and a magnet turned inside a coil N S coil turned slip rings brushes a.c. output (a) coil turned in a magnetic field S N magnet turned a.c. output coil (cut through) (b) magnet turned inside a coil
Figure 2. Two generators: coil turned in a field (a); magnet turned in a coil (b).

Turn the generator

Loading the interactive…

Output voltage of a generator against time, at two speeds time voltage 0 A B steady speed twice as fast: 2 × peak, 2 × frequency A peak: coil sides move at right angles to the field B zero: coil sides move along the field lines
Figure 3. Generator output voltage against time.

The same three factors increase a generator's voltage. Turning faster also raises the frequency (Figure 3).

3Transformers: structure and action (6.17P) Paper 2 only

A transformer is two coils of insulated wire — the primary (input) and the secondary (output) — wound on the same soft iron core. The coils are not connected to each other; energy is passed by the changing magnetic field in the core. Soft iron is used because it magnetises and demagnetises easily as the field reverses.

  • Step-up: more turns on the secondary (Ns > Np) → output voltage larger than input.
  • Step-down: fewer turns on the secondary (Ns < Np) → output voltage smaller.

A transformer only works with a.c. A direct current gives a steady field in the core, which induces no voltage in the secondary.

Structure of a transformer, and how it works a.c. input voltage Vp output voltage Vs primary coil: Np turns secondary coil: Ns turns soft iron core a.c. in the primary coil changing magnetic field in the core changing field passes through the secondary alternating voltage induced in the secondary
Figure 4. A transformer and how it works.

Wind the transformer

Loading the interactive…

4Transformer equations (6.19P, 6.20P) Paper 2 only

Equations — recall both; they are not given in the exam

Vp / Vs = Np / Ns — input (primary) voltage ÷ output (secondary) voltage = primary turns ÷ secondary turns

Vp × Ip = Vs × Is — input power = output power (for 100% efficiency)

Vp, Vs = primary and secondary voltages (V) · Np, Ns = numbers of turns (no unit) · Ip, Is = primary and secondary currents (A). Keep primary over secondary on both sides.

Worked example

A transformer changes 230 V to 11.5 V. The primary has 2000 turns and the secondary current is 4.0 A.

  • Secondary turns: Ns = Np × Vs ÷ Vp = 2000 × 11.5 ÷ 230 = 100 turns
  • Primary current: Ip = VsIs ÷ Vp = 11.5 × 4.0 ÷ 230 = 0.20 A

Power in = power out, so if a transformer raises the voltage it lowers the current by the same factor. It cannot give out more power than it takes in.

5Transformers in transmission (6.18P) Paper 2 only

  1. A step-up transformer at the power station raises the voltage to a very high value.
  2. For the same power (P = V × I), a higher voltage means a smaller current in the cables.
  3. A smaller current heats the cables less, so less energy is wasted during transmission.
  4. A step-down transformer near homes lowers the voltage to a safe value (230 V mains).
Step-up and step-down transformers in electricity transmission power station step-up transformer step-down transformer homes generates a.c. voltage ↑ to hundreds of kV, current ↓ high voltage, small current: little energy wasted voltage ↓ to 230 V
Figure 5. Transformers between the power station and homes.

Send power down the line

Loading the interactive…

Quick check

12 multiple-choice questions. Pick an answer to see whether it is right and why.

  1. A bar magnet is held still inside a coil connected to a centre-zero meter. What does the meter show?

  2. Which change increases the voltage induced when a magnet is pushed into a coil?

  3. Pushing the N pole of a magnet into a coil makes a meter deflect to the right. What happens when the N pole is pulled out?

  4. A wire is moved between the poles of a magnet, along the direction of the field lines. Why is no voltage induced?

  5. Why is the output of a generator with a coil turning in a magnetic field alternating?

  6. What is the job of the slip rings and brushes in a generator?

  7. The coil of a generator is turned faster. How does its output change?

  8. Why does a transformer not work with a direct current in the primary coil?Paper 2 only

  9. A transformer has 1000 turns on its primary coil and 50 turns on its secondary coil. The primary voltage is 230 V. What is the secondary voltage?Paper 2 only

  10. A 100% efficient transformer has a primary voltage of 240 V and a primary current of 0.5 A. The secondary voltage is 12 V. What is the secondary current?Paper 2 only

  11. Which describes a step-up transformer?Paper 2 only

  12. Why is electricity transmitted along cables at a very high voltage?Paper 2 only

Exam-style questions

Write your answer, then show the answer and compare. Nothing here is marked for you: you decide how close you were. What you write is saved in this browser.

Induction and generators (6.15, 6.16)

1

A magnet is pushed into a coil connected to a centre-zero meter, and the needle deflects to the right. State what the needle does when the magnet is: (a) held still inside the coil; (b) pulled out; (c) pushed in faster.

3 marks
2

Describe two ways to induce a voltage in a wire, and state three factors that affect the size of the induced voltage.

5 marks
3

A wire is moved between the poles of a magnet but no voltage is induced. Suggest why.

1 mark
4

Describe how a coil rotating in a magnetic field generates an alternating voltage.

4 marks
5

The coil of a generator is turned twice as fast. Describe how the graph of output voltage against time changes.

2 marks
6

A bicycle dynamo has a magnet that turns inside a fixed coil. Explain why an alternating voltage is induced in the coil.

2 marks

Transformers (6.17P–6.20P) — Paper 2 only

7

Describe the structure of a transformer.

3 marks
8

Explain how a transformer produces an output voltage, and why it does not work with a d.c. supply.

4 marks
9

A transformer has 500 turns on the primary coil and 25 turns on the secondary. The input voltage is 230 V. Calculate the output voltage and state whether it is a step-up or step-down transformer.

3 marks
10

A 100% efficient transformer has an input of 230 V and 0.5 A. The output voltage is 11.5 V. Calculate the output current.

3 marks
11

Explain why electricity is transmitted through the cables at a very high voltage, and why a step-down transformer is used before homes.

4 marks

How well do you know this?

Rate each specification point. It is saved to your tracker as a new revision round.

All points:
  • 6.15know that a voltage is induced in a conductor or a coil when it moves through a magnetic field or when a magnetic field changes through it and describe the factors that affect the size of the induced voltage
  • 6.16describe the generation of electricity by the rotation of a magnet within a coil of wire and of a coil of wire within a magnetic field, and describe the factors that affect the size of the induced voltage
  • 6.17Pdescribe the structure of a transformer and understand that a transformer changes the size of an alternating voltage by having different numbers of turns on the input and output sides
  • 6.18Pexplain the use of step-up and step-down transformers in the large-scale generation and transmission of electrical energy
  • 6.19Pknow and use the relationship between input (primary) and output (secondary) voltages and the turns ratio for a transformer
  • 6.20Pknow and use the relationship: input power = output power

Settings

Your subjects

Untick the subjects you don't take. They leave the menu, the home page and the tracker. Your ratings are kept, so you can bring a subject back at any time.