1The three wires (2.2)
Mains electricity is supplied at about 230 V. A mains cable has three wires:
| Wire | Colour | Job |
|---|---|---|
| live | brown | carries the high alternating voltage to the appliance — the dangerous wire |
| neutral | blue | completes the circuit; stays close to 0 V |
| earth | green and yellow | joined to any metal case; carries a current only when there is a fault |
The fuse (or circuit breaker) and the switch are always in the live wire, so that breaking the circuit disconnects the appliance from the high voltage. In the neutral wire they would leave the appliance live even when it is off.
2Protecting the device and the user (2.2)
| Feature | How it works | What it protects |
|---|---|---|
| Insulation | Plastic covers every wire. Plastic is an insulator, so no current can pass to a person who touches the cable. | the user (no shock) |
| Double insulation | Insulated wires and an insulating (plastic) casing, with no touchable metal part that could become live. Needs no earth wire (two‑core cable). Marked with a square inside a square. | the user |
| Earthing | The earth wire joins the metal case to earth, so a fault current flows to earth and blows the fuse (Figure 1). | the user — the case cannot stay live |
| Fuse | A thin wire in the live wire. If the current is bigger than its rating, the fuse wire melts and breaks the circuit. It must be replaced. | the device and its cable — stops overheating and fire; with earthing, the user too |
| Circuit breaker | An automatic switch in the live wire that opens (trips) when the current is bigger than a set value. It acts faster than a fuse and is reset, not replaced. | as a fuse |
3Why a current heats a resistor (2.3)
Energy is transferred electrically from the supply to the thermal energy store of the resistor, which then heats its surroundings. The bigger the current, the greater the heating.
Uses in the home. Every appliance with a heating element (a resistance wire): kettle, toaster, electric heater, hairdryer, iron, oven, immersion heater. The filament of a filament lamp gets hot enough to glow.
4Power and choosing a fuse (2.4)
power = current × voltage P = I × V
P in watts (W) · I in amperes (A) · V in volts (V). Power is the energy transferred each second.
Choosing a fuse
- Work out the normal current: I = P ÷ V.
- Choose the fuse with the lowest rating that is above that current (common ratings 3 A, 5 A, 13 A).
A 2.8 kW kettle on 230 V: I = 2800 ÷ 230 = 12.2 A → 13 A fuse.
A 60 W lamp on 230 V: I = 60 ÷ 230 = 0.26 A → 3 A fuse.
A rating below the normal current and the fuse melts in normal use. A rating far above it and the fuse may not melt when a fault makes the current too big, so the cable can overheat.
5Energy transferred (2.5)
energy transferred = current × voltage × time E = I × V × t
E in joules (J) · I in A · V in V · t in seconds. Since P = I × V, this is also E = P × t.
A heater takes 8.0 A from the 230 V mains for 15 minutes: t = 15 × 60 = 900 s, so E = 8.0 × 230 × 900 = 1 656 000 J ≈ 1.7 MJ.
6Alternating and direct current (2.6)
Direct current (d.c.) — current that flows in one direction only; supplied by a cell or battery.
Alternating current (a.c.) — current that repeatedly reverses direction; mains electricity is a.c.
UK mains is a.c. at 50 Hz: 50 complete cycles (forwards, then back) every second.
| Wrong | Right |
|---|---|
| The earth wire carries a current all the time. | Only when there is a fault. |
| A fuse protects you from electric shocks. | It melts only at large currents, to stop overheating; it protects you only together with the earth wire. |