Penetrating power of radiation: the method
Aim. Find which absorbers stop the radiation from a source, and so identify it. Specification point 7.6.
Equipment
- GM tube and counter
- Lead-lined box of sources
- Source (in tongs)
- Paper
- 3 mm aluminium
- 10 mm lead
Method
- With no source nearby, count for 1 minute.
- Record: background count per minute.
- Take the source out of the box with tongs and fix it 3 cm from the GM tube.
- Record: count for 1 minute with no absorber.
- Put the paper between them and count again.
- Record: count with paper.
- Replace it with the aluminium.
- Record: count with aluminium.
- Repeat each count and average; then try the lead.
- Work out: corrected count with no absorber = 420 − background.
- Put the source back in its lead-lined box at once.
What earns the marks
- Background count measured first
- Source handled with tongs, at a fixed distance
- Repeats: decay is random; background subtracted
- Stopped by a few mm of aluminium, not paper → beta
- Source returned at once; short exposure, kept at a distance
What you should find
Corrected counts: 400 with no absorber, 395 with paper, 3 with 3 mm aluminium: the radiation passes through paper but is stopped by a few millimetres of aluminium, so it is beta. Background is subtracted; the source is handled with tongs and returned at once.