Specific heat capacity of water: the method
Aim. Find the specific heat capacity of 0.50 kg of water. Specification point 5.14P · Paper 2.
Equipment
- Balance
- Insulated beaker of water, with a lid
- Immersion heater
- Thermometer
- Joulemeter
- Power supply
Method
- Weigh the water (in the beaker, minus the beaker).
- Record: record the mass in kg.
- Put it back, and put the heater in the water.
- Put the thermometer in the water.
- Wrap it in insulation and put the lid on.
- Connect the heater through the joulemeter to the supply. Zero the joulemeter.
- Record: record the starting temperature.
- Switch on for about 10 minutes.
- Switch off. Watch: record the highest temperature it reaches.
- Record: highest temperature.
- Record: read the joulemeter.
- Work out: c = E ÷ (m × ΔT) = 23000 ÷ (0.50 × 10). Nearest whole number.
What earns the marks
- Mass measured
- Stirred before each reading
- Insulated to reduce energy lost
- Joulemeter zeroed
- Highest temperature recorded (it keeps rising briefly)
- ΔQ = m × c × ΔT rearranged
- Energy lost → ΔT too small → c too high; improve with more insulation
What you should find
23000 J raised 0.50 kg of water by 10 °C: c = 23000 ÷ (0.5 × 10) ≈ 4600 J/kg °C. It is higher than the true value because some energy is lost to the surroundings.