Temperature change: neutralisation: the method
Aim. Find whether hydrochloric acid neutralising sodium hydroxide solution is exothermic or endothermic. Specification point 3.8, 3.2.
Equipment
- Beaker (to hold the cup)
- Polystyrene cup
- Hydrochloric acid (25 cm³)
- Thermometer
- Stirring rod
- Sodium hydroxide solution (25 cm³)
Method
- Stand the polystyrene cup in the beaker.
- Measure 25 cm³ of hydrochloric acid into the cup.
- Put the thermometer in the cup.
- Record: record the starting temperature.
- Add 25 cm³ of sodium hydroxide solution.
- Put the lid on.
- Stir, and watch the thermometer.
- Record: record the highest temperature.
- Work out: temperature change ΔT = final − start (include the sign).
What earns the marks
- Cup stood in a beaker so it does not tip over
- Measured volume of the second solution
- Lid on to reduce heat loss
- Stirred to mix
- Highest temperature recorded
- Temperature rise = exothermic; fall = endothermic
- Heat lost to (or gained from) the surroundings
What you should find
Hydrochloric acid neutralising sodium hydroxide solution: the temperature went from 21.0 °C to 27.5 °C (ΔT = +6.5 °C), so it is exothermic. An insulated cup with a lid cuts heat exchange with the surroundings.