EEasy IGCSELabTracker

On a phone the notes, quizzes and tracker work fine. The 3D models and the practice lab are made for a laptop.

Enzymes and pH

Enzymes and pH: the method

Aim. Find how pH affects the rate at which amylase digests starch. Specification point 2.14B · Paper 2.

Equipment

  • Starch tube
  • Amylase tube
  • Water bath
  • Spotting tile
  • Starch solution
  • Amylase solution
  • Iodine solution
  • pH 7 buffer
  • Dropping pipette
  • Stop clock

Method

  1. Put one drop of iodine solution in each well of the spotting tile.
  2. Put 2 cm³ of starch solution in the starch tube.
  3. Put 2 cm³ of amylase solution in the amylase tube.
  4. Add 1 cm³ of pH 7 buffer to the starch.
  5. Stand the starch tube in the water bath at 35 °C.
  6. And the amylase tube.
  7. Leave them for 5 minutes.
  8. Pour the amylase into the starch (keep it in the bath)…
  9. …and start the clock.
  10. After 30 s, put a drop of the mixture into the first well.
  11. Keep adding a drop to the next well every 30 s until the iodine stays orange-brown.
  12. Record: record the time when the iodine first stayed orange-brown at pH 7.
  13. Work out: rate = 1 ÷ time. Work it out to 2 significant figures.
  14. Repeat at pH 3, 5, 9 and 11, three times each, and take means.
  15. Control: repeat at pH 7 with boiled amylase.

What earns the marks

  • Iodine in every well before starting
  • Same volumes each time
  • A buffer solution sets the pH
  • Temperature kept the same (water bath)
  • Both reach the temperature before they are mixed
  • Timed from the moment of mixing
  • Sampled at a fixed interval (every 30 s)
  • Time recorded when the starch had gone
  • At least five pH values, each repeated, with a mean
  • Boiled (denatured) amylase control
  • The rate is highest at the optimum pH
  • Denatured: active site changed, substrate no longer fits
What you should find

Amylase digested starch fastest at about pH 7 (60 s); more slowly at pH 5 and 9; at pH 3 and 11 the starch never went because the enzyme was denatured. The buffer sets the pH; the temperature is kept the same in the water bath.